1860 MPa low relaxation strand is a high-strength, seven-wire prestressing steel product used to introduce and maintain tensile force in concrete structures. “1860 MPa” identifies its nominal tensile-strength class, while “low relaxation” describes its controlled loss of stress over time under specified conditions. It is commonly supplied as prestressing concrete (PC) strand, with exact diameter, construction, mechanical properties, and acceptance criteria defined by the project specification and applicable standard. At DALU, we help buyers check those requirements before requesting a quotation or confirming an order.

Check now

Key points at a glance

  • 1860 MPa refers to the strand’s tensile-strength class; it does not specify the strand diameter or prestressing force.
  • Low-relaxation performance helps limit stress loss in prestressed concrete, but results depend on the specified test conditions and product standard.
  • Common uses include prestressed beams, bridge components, concrete piles, and post-tensioning systems.
  • Buyers should confirm the governing standard and edition, nominal diameter, strand construction, coating, packaging, and required inspection documents.

What is 1860 MPa low relaxation strand?

Definition and construction

PC strand is a steel tendon made by twisting high-carbon steel wires together. A common construction is one center wire surrounded by six helically wound wires, forming a seven-wire strand. The steel is processed to meet specified strength and relaxation requirements for prestressing applications.

The 1860 MPa designation refers to a tensile-strength level, not the stress that must be applied during installation. Actual stressing force is determined by the structural design, tendon system, and installation procedure. An engineer or project specification should define allowable stressing loads and related safety requirements.

What “low relaxation” means

When a prestressing strand is held under sustained load, its stress can decrease over time. This loss is known as relaxation, and low-relaxation strand is manufactured and evaluated to limit that loss under the conditions defined by the relevant standard. The term does not mean zero relaxation, nor does it by itself state the performance of a complete concrete member.

For example, some standards specify a relaxation limit of up to 2.5% after 1,000 hours under defined test conditions. The applicable limit, test stress, temperature, and other details must be checked in the governing standard and project documents. Buyers should avoid comparing relaxation figures unless the test conditions and acceptance criteria are equivalent.

Core functions in prestressed concrete

Prestressing strand places concrete under compression by applying tensile force to the steel tendon. This can help a designed concrete element resist service loads and control cracking or deflection. The structural outcome depends on the member design, concrete properties, tendon layout, anchorage, installation, and environmental conditions.

Low-relaxation properties are relevant because sustained prestressing force may change over time. Specifying compliant strand helps the design team account for one source of prestress loss, alongside losses associated with concrete shrinkage and creep, friction, anchorage seating, and other project-specific factors. The strand does not replace correct design, installation, or quality control.

Applications and product options

Common application scenarios

  • Bridge construction: Prestressed girders and other concrete components where the design uses tensioned steel tendons.
  • Precast concrete: Beams, slabs, sleepers, and other elements produced with prestressing beds or approved systems.
  • Post-tensioning: Tendons installed and stressed after concrete placement, when specified for the structural system.
  • Concrete piles and infrastructure: Prestressed products designed for their required handling, service, and loading conditions.

Applications are not interchangeable by default. A strand suitable for one production method or tendon system may not meet another project’s requirements for diameter, coating, anchorage compatibility, or documentation. Confirm the intended use with the engineer, contractor, or system supplier before placing an order.

Types and material options

Buyers may encounter strand described by nominal diameter, seven-wire construction, strength class, surface condition, and coating. Uncoated strand is common, while galvanized or other coated options may be specified for particular exposure or system requirements. Coatings can affect dimensions, handling, bond, or compatibility, so they should only be selected when accepted by the design and applicable standard.

DALU contains other products and information you need, so please check it out.

Nominal diameters such as 12.7 mm and 15.2 mm are widely used in the market, but they are not universal project requirements. Strand mass, breaking force, and dimensional tolerances vary with diameter and standard. Confirm the exact product designation rather than relying on a strength grade alone.

Key specifications and applicable standards

Specifications usually define more than the tensile-strength class. A procurement schedule may include nominal diameter, strand construction, minimum breaking force, yield or proof-force requirements, elongation, relaxation limit, dimensional tolerances, surface condition, and test or inspection documentation. The contract should also state the required delivery condition and packaging.

Specification item What the buyer should verify
Strength class Confirm that 1860 MPa is the required class and check the associated mechanical acceptance values.
Diameter and construction State the nominal diameter, seven-wire construction, and any dimensional tolerances required by the project.
Relaxation Check the maximum permitted loss, test duration, initial stress, temperature, and standard method.
Standard and edition Specify the exact standard, edition, amendments, and any project-specific requirements.
Inspection documents Define required test reports, certificates, traceability details, and inspection arrangements before shipment.

Standards that may be specified for prestressing strand include ASTM A416/A416M, EN 10138-3, and China’s GB/T 5224. Requirements and terminology can differ between standards, editions, and product grades. A designation in one standard should not be treated as automatically interchangeable with a designation in another; the project engineer or purchaser should approve any equivalence.

How B2B buyers can assess suitability

Selection factors

Start with the project documents, not a generic catalogue description. Confirm the design’s required strength class, diameter, strand type, standard, and any restrictions on coating or surface condition. Then check that the intended anchorage and stressing equipment are compatible with the selected strand.

Next, establish the inspection and delivery requirements. Ask how the product will be identified by lot, what mechanical test records are available, and how coils or reels will be protected and marked. For international sourcing, also align packing, shipping terms, lead-time expectations, and document format before order confirmation.

Common procurement mistakes

  • Ordering by “1860 MPa” alone without stating the diameter, standard, and required mechanical values.
  • Comparing relaxation results without checking that the test method and conditions match.
  • Assuming that strand compliant with one national standard automatically satisfies another.
  • Leaving coating, packaging, traceability, or inspection documents undefined until after production.

Supplier support from DALU

As a supplier of 1860 MPa low relaxation strand, we can review the buyer’s requested product designation, standard, diameter, order quantity, packaging, and delivery destination before quotation. This helps identify missing details that could otherwise delay technical approval or order processing. We can also discuss the inspection documents and product identification required for the purchase, subject to the agreed specification and available production records.

To request a quotation, send us the project standard and edition, strand diameter, required quantity, coating or surface condition, packaging preference, destination, and target delivery schedule. If the specification is still under review, share the relevant requirement or schedule so we can help clarify the information needed for a purchase-ready inquiry. Final product acceptance should follow the approved project documents and applicable inspection procedures.

Conclusion

1860 MPa low relaxation strand is seven-wire prestressing steel in a defined tensile-strength class, manufactured to limit stress loss under specified test conditions. It is used in a range of prestressed concrete applications, but the strength designation alone is not enough to select the correct product. Buyers should verify the diameter, mechanical requirements, relaxation criteria, standard and edition, coating, and documentation against the project specification.